Specifications
Summary
|
|
C12-400-LP Propane-Fired Cremation System complete
with two burners, secondary chamber, stack, timers, and temperature control
C12-400-N Natural Gas-Fired Cremation System
complete with two burners, secondary chamber, stack, timers, and temperature
control
|
|
WASTE CHAMBER
Chamber capacity
(Type 4 waste-pathological) 400 lbs 181 kg
|
INSTALLATION
Must be installed in accordance with local codes and
ordinances, subject to regulatory agencies.
Outside installation is recommended with a simple metal roof or
three-sided metal shelter, providing a minimum of four foot clearance from
any combustible roof materials.
Minimum of 18 clearance is required for penetration of combustible
roof materials. Inside installations
may have special insurance requirements.
Factory must be advised.
|
|
Chamber volume (approximate) 12 cu. ft. 3.7 cu. m.
|
|
Chamber size (outside) Width
36
91 cm
Height 34 86 cm
Length 48 122 cm
|
|
Door opening 22
x 29 56 cm x 74 cm
|
|
Height to door 30 76 cm
|
|
Height to top of secondary chamber 7-1 2.2 m
|
GENERAL
Electrical service
Standard 115 volt, 60 HZ, 20 amp
Also available 220 volt, 50 HZ, 10 amp
BURNERS
LP or Natural gas burner with spark ignition and
flame safety shut-off.
OPERATION
2 manual timers
TOTAL WEIGHT
3000 lbs. (approximate) 1361 kg
|
|
Overall dimensions (w/stack) 16H x 53Wx 61W 4.9m
x 135 cm x 155cm
|
|
Suggested slab size (l x w x thick) 10 x 12 x 6 3.0 m x 3.7m x 15cm
|
|
STACK
Dimensions (OD) 14 36 cm
|
|
Material 14 gauge Aluminized Steel
Jacket, refractory lined
|
|
REFRACTORY THICKNESS
Primary 3.0(2800F) 7.6 cm
Secondary 1.5(2800F) 3.8 cm
Stack 1.5(2800F) 3.8 cm
|
|
C12-400-LP C12-400-N
|
*Approximate reduced fuel consumption of lower burner
is a result of burner cycling on & off.
|
|
APP. FUEL CONSUMPTION LP NATURAL GAS
Upper burner 4.1 GPH
392 CFH
Lower burner 3.0 GPH 275 CFH
(1.5 GPH*) (138 CFH*)
APPROXIMATE BTUH
Upper burner 414,000 415,000
Lower burner 275,000 275,000
|
|
* Fuel consumption approximate. Actual fuel use depends
on BTU content of waste. Consult factory for retention times or special
requirements
|