Animal Crematory Systems:
P25 and P25-M1 Series

Since
1962, Shenandoah has built high quality cremation
equipment designed for economical ease of use.
Member
of the National Animal Control Association and
International Association of Pet Cemeteries
- How is your facility managing animal carcasses?
- Do you have waste management under control?
- How much do you spend each year to have carcasses hauled
to landfills?
- How long will these sites be available? And at what
future cost?
- Who is ultimately responsible for proper carcass
disposal?
One
simple solution to animal carcass disposal 
Animal carcasses generated at your facility can cause a
serious disposal problem. A Shenandoah crematory system is a safe,
easy and economical solution.
The P25 is designed to burn Type IV pathological waste that can and should
be destroyed on-site. Certain
models can also handle infectious and contaminated "red bag," surgical
dressings, plastic test devices and other wastes. If you are paying a high fee
to haul these waste materials to a disposal site, now is the time
to consider the on-site cremation alternative.
On-site cremation is a thorough, fast, and cost effective way
to dispose of carcasses. Shenandoah's P25 crematory system
destroys pathogens. Our various models are engineered to meet
strict air emission regulations without offensive smoke or odor.
The P25-M1 provides a one (1) second retention of
emissions in the secondary burn chamber.
Shenandoah has been building crematory systems since 1962. We
have earned the reputation of making quality products that are:
- easy to install and operate
- very affordable
- extremely durable
- backed by knowledgeable and friendly service
Benefits and Features of
Shenandoah's P25
Fast, complete,
efficient waste disposal
- Heavy duty ceramic grates allow burning from below.
- Concave refractory bottom acts as a hearth for waste that
falls through grate openings.
- Insulated and refractory lined secondary chamber with
exit temperatures of up to 1800° F and one (1) second
retention with model M1.
Minimum installation
and start up time
- Factory assembled, aluminized steel jacket lined with
refractory and firebrick.
- Monitors, recorders and other accessory equipment
available.
Easy and safe
operation
- Large counter-balanced fill door with electrical lockout.
- Automatic control system provides preset burn times and
shut off.
- Reload light indicates to operator when it is time to
recharge.
Low energy consumption
levels
- Programmable digital temperature controls maintain
temperature, assuring complete combustion while
conserving fuel.
- Pressure blower with modulating air control creates
turbulence and distributes combustion air to secondary
chamber.
- Secondary burner with temperature activated modulating
control provides fast preheat and sustains high
temperature performance at low energy consumption levels.
Charging rate
- Up to 1,200 pounds per ten-hour day of Type IV
pathological waste rated at 1,000 BTU's per pound. Based
on batch loading twice daily. Dependent upon reloading
regulations. Additional time may be required for burnout
of final charge.
Models
- P25-2GLP-T Propane fired cremation
system complete with two burners, secondary chamber,
stack, timer and digital temperature control.
- P25-2GN-T Natural gas fired cremation
system complete with two burners, secondary chamber,
stack, timer and digital temperature control.
- P25-2O-T Oil fired cremation system
complete with two burners, secondary chamber, stack,
timer and digital temperature control.
- P25-2GLP-M1 Propane fired cremation
system complete with two burners, secondary chamber,
stack, timer and digital temperature control, and one
second retention.
- P25-2GN-M1 Natural gas fired cremation
system complete with two burners, secondary chamber,
stack, timer and digital temperature control, and one
second retention.
Specifications Summary
| |
P25 |
P25-M1 |
| Weight |
7500 lbs. approximately |
9400 lbs. approximately |
| Primary chamber volume (above grates) |
23 cu. ft. |
23 cu. ft. |
| Primary chamber dimensions (internal) |
28 1ž2" high, 24 1ž2" wide, 60" long |
28 1ž2" high, 24 1ž2" wide, 60" long |
| Fill door opening |
24" x 28" |
24" x 28" |
| Ash door opening |
8" x 16" |
8" x 16" |
| Secondary chamber dwell time |
.3 seconds |
1 second |
| Secondary chamber preheat |
1400° F |
1800° F |
| Secondary chamber operating temperature |
1800° F with waste burning |
1800° F |
| Overall dimensions with stack and burners |
4' wide x 23' high x 7.5' long |
5' wide x 25.2' high x 8.5' long |
| Height to top of secondary chamber |
9'2" |
11'9" |
| Height to fill door |
45" |
45" |
| Diameter of secondary chamber |
27" O.D. |
38" O.D. |
| Diameter of stack |
18" O.D. |
18" O.D. |
| Suggested pad size |
10' x 12' x 6" thick |
10' x 12' x 6" thick |
| Gas service |
1,200,000 BTUH |
1,600,000 BTUH |
| Electrical service |
115V 60 Hz. 30 amp |
115V 60 Hz. 30 amp |
| |
P25
|
P25-M1
|
| LP |
Natural Gas |
LP |
Natural Gas |
| Fuel consumption* |
4.0 GPH |
400 CFH |
6.0 GPH |
600 CFH |
| Approximate BTUH: |
| Upper burner |
800,000 |
800,000 |
1,200,000 |
1,200,000 |
| Lower burner |
319,000 |
335,000 |
319,000 |
335,000 |
| *Fuel consumption
approximate. Actual fuel use depends on BTU content of
waste. Consult factory for longer retention times or