Medical Waste Incineration Systems:
P25-M2 Series

Since
1962, Shenandoah has built high quality incineration
equipment designed for economical ease of use.
- How is your facility disposing of medical waste?
- Do you have waste management under control?
- How much do you spend each year to have waste material
hauled to landfills?
- How long will these sites be available? And at what
future cost?
- Who is ultimately responsible for proper waste disposal?
One
simple solution to medical waste disposal 
Infectious waste material generated at health care facilities
can cause a serious disposal problem. A Shenandoah incinerator is
a safe, easy and economical solution.
The P25 is designed to burn disposables that can and should be destroyed on-site.
These wastes include
infectious and contaminated "red bag," surgical dressings, plastic
test devices and other wastes. If you are paying a high fee to haul these waste
materials to a disposal site, now is the time to consider the on-site
incineration alternative.
On-site incineration is a thorough, fast, and cost effective
way to dispose of medical waste. Shenandoah's P25 incinerator
destroys pathogens. Our various models are engineered to meet
strict air emission regulations.
Shenandoah has designed and manufactured incinerators since
1962, earning the reputation of making quality products that are:
- easy to install and operate
- very affordable
- extremely durable
- backed by knowledgeable and friendly service
Benefits and Features of Shenandoah's
P25-M2
Fast, complete,
efficient waste disposal
- Dual chamber combustion.
- Chambers insulated and lined with high temperature
refractory.
- Heavy duty ceramic grates allow burning from below.
- Concave refractory bottom acts as a hearth for waste that
falls through grate openings.
- Insulated and refractory lined secondary chamber with
preheat and exit temperatures of up to 1800° F and two
(2) second retention.
Minimum installation
and start up time
- Modular components, factory designed to keep installation
simple. Most piping and wiring is completed at the
factory, simplifying most connections to single-point
hook up.
- Distributor assistance available for permitting, start
up, operator training and testing.
- Factory assembled, aluminized steel jacket lined with
refractory and firebrick.
Easy and safe
operation
- Large counter-balanced fill door with electrical lockout.
- Automatic control system provides preset burn times and
shut off.
- Reload light indicates to operator when it is time to
recharge.
- Temperatures in primary and secondary chambers are
recorded by a dual pen circular chart recorder.
- De-ashing is done at the beginning of the work day when
unit is cool.
- Minimum operator involvement and maintenance.
Low energy consumption
levels
- Programmable digital temperature controls maintain
temperature, assuring complete combustion while
conserving fuel.
- Pressure blower with modulating air control creates
turbulence and distributes combustion air to secondary
chamber.
- Secondary burner with temperature activated modulating
control provides fast preheat and sustains high
temperature performance at low energy consumption levels.
Dependable support
- With combustion design and manufacturing experience since
1962, Shenandoah is a leading supplier to the health
services professions.
- Nationwide network of distributors work with the customer
to determine disposal needs, coordinate design,
fabrication, factory testing, installation, start up, and
field testing of the equipment, providing quality
operator training.
Charging rate
- Up to 500 pounds per ten-hour day of typical red bag
waste rated at 10,000 BTU's per pound with up to 10%
pathological material rated at 1,000 BTU's per pound.
Based on batch loading up to eight (8) times per day.
Dependent upon density, BTU value of the waste and
subject to reloading regulations. Additional time may be
required for burnout of final charge.
- Up to 1,200 pounds per ten-hour day of Type IV
pathological waste rated at 1,000 BTU's per pound. Based
on batch loading twice daily. Dependent upon reloading
regulations. Additional time may be required for burnout
of final charge.
Models
- P25-3GLP-M2 Propane fired incineration
system complete with two burners, secondary chamber,
stack, timer and digital temperature control, with two
second retention.
- P25-3GN-M2 Natural gas fired
incineration system complete with two burners, secondary
chamber, stack, timer and digital temperature control,
with two second retention.
Specifications Summary
| Primary chamber volume (above grates) |
23.3 cu. ft.3 |
| Primary chamber dimensions (internal) |
28 1ž2" high, 24 1ž2" wide, 60" long |
| Secondary chamber dimensions (external): |
Upper section |
96" L x 42" D |
| Lower section |
84" L x 38" D |
| Secondary chamber volume |
77 ft.3, incl. crown |
| Secondary preheat temperature |
1800° F |
| Secondary operating temperature |
1800° F |
| Secondary chamber dwell time |
2 seconds |
| Height to top of secondary chamber |
16' |
| Height to fill door |
45" |
| Fill door opening |
24" x 28" |
| Ash door opening |
8" x 16" |
| Stack dimensions |
20" O.D. x 16" I.D. x 49" L |
| Insulation |
1", 1900° F mineral wool |
| Overall dimensions |
8'9" L x 5' W x 28'3" H |
| Total weight |
11,500 lbs. approx. |
| Suggested pad size |
15' W x 20' L x 6" thick |
| Gas service |
2,750,000 BTUH |
| Electrical service |
115V 60 Hz. 30 amp |
| Fuel consumption* |
Natural gas - 600 CFH |
| LP - 6.0 GPH |
*Fuel consumption approximate. Actual
fuel use depends on waste density,
BTU value and reloading frequency. |
|