Medical Waste Incineration Systems:
P25 and P25-M1 Series

Since
1962, Shenandoah has built high quality incineration
equipment designed for economical ease of use.
- How is your facility disposing of medical waste?
- Do you have waste management under control?
- How much do you spend each year to have waste material
hauled to landfills?
- How long will these sites be available? And at what
future cost?
- Who is ultimately responsible for proper waste disposal?
One
simple solution to medical waste disposal 
Infectious waste material generated at health care facilities
can cause a serious disposal problem. A Shenandoah incinerator is
a safe, easy and economical solution.
The P25 is designed to burn disposables that can and should be destroyed on-site.
These wastes include
infectious and contaminated "red bag," surgical dressings, plastic
test devices and other wastes. If you are paying a high fee to haul these waste
materials to a disposal site, now is the time to consider the on-site
incineration alternative.
On-site incineration is a thorough, fast, and cost effective
way to dispose of medical waste. Shenandoah's P25 incinerator
destroys pathogens. Our various models are engineered to meet
strict air emission regulations.
Shenandoah has designed and manufactured incinerators since
1962, earning the reputation of making quality products that are:
- easy to install and operate
- very affordable
- extremely durable
- backed by knowledgeable and friendly service
Benefits and Features of
Shenandoah's P25
Fast, complete,
efficient waste disposal
- Heavy duty ceramic grates allow burning from below.
- Concave refractory bottom acts as a hearth for waste that
falls through grate openings.
- Insulated and refractory lined secondary chamber with
exit temperatures of up to 1800° F and up to one (1)
second retention.
Minimum installation
and start up time
- Factory assembled, aluminized steel jacket lined with
refractory and firebrick.
- Monitors, recorders and other accessory equipment
available.
Easy and safe
operation
- Large counter-balanced fill door with electrical lockout.
- Automatic control system provides preset burn times and
shut off.
- Reload light indicates to operator when it is time to
recharge.
Low energy consumption
levels
- Programmable digital temperature controls maintain
temperature, assuring complete combustion while
conserving fuel.
- Pressure blower with modulating air control creates
turbulence and distributes combustion air to secondary
chamber.
- Secondary burner with temperature activated modulating
control provides fast preheat and sustains high
temperature performance at low energy consumption levels.
Charging rate
- Up to 500 pounds per ten-hour day of typical red bag
waste rated at 10,000 BTU's per pound with up to 10%
pathological material rated at 1,000 BTU's per pound.
Based on batch loading up to eight (8) times per day.
Dependent upon density, BTU value of the waste and
subject to reloading regulations. Additional time may be
required for burnout of final charge.
- Up to 1,200 pounds per ten-hour day of Type IV
pathological waste rated at 1,000 BTU's per pound. Based
on batch loading twice daily. Dependent upon reloading
regulations. Additional time may be required for burnout
of final charge.
Models
- P25-2GLP-T Propane fired incineration
system complete with two burners, secondary chamber,
stack, timer and digital temperature control.
- P25-2GN-T Natural gas fired incineration
system complete with two burners, secondary chamber,
stack, timer and digital temperature control.
- P25-2O-T Oil fired incineration system
complete with two burners, secondary chamber, stack,
timer and digital temperature control.
- P25-2GLP-M1 Propane fired incineration
system complete with two burners, secondary chamber,
stack, timer and digital temperature control, with one
second retention.
- P25-2GN-M1 Natural gas fired
incineration system complete with two burners, secondary
chamber, stack, timer and digital temperature control,
with one second retention.
Specifications Summary
| |
P25 |
P25-M1 |
| Weight |
7500 lbs. approximately |
9400 lbs. approximately |
| Primary chamber volume (above grates) |
23 cu. ft. |
23 cu. ft. |
| Primary chamber dimensions (internal) |
28 1ž2" high, 24 1ž2" wide, 60" long |
28 1ž2" high, 24 1ž2" wide, 60" long |
| Fill door opening |
24" x 28" |
24" x 28" |
| Ash door opening |
8" x 16" |
8" x 16" |
| Secondary chamber dwell time |
.3 seconds |
1 second |
| Secondary chamber preheat |
1200° F |
1800° F |
| Secondary chamber operating temperature |
1800° F with waste burning |
1800° F |
| Overall dimensions with stack and burners |
4' wide x 23' high x 7.5' long |
5' wide x 25.2' high x 8.5' long |
| Height to top of secondary chamber |
9'2" |
11'9" |
| Height to fill door |
45" |
45" |
| Diameter of secondary chamber |
27" O.D. |
38" O.D. |
| Diameter of stack |
18" O.D. |
18" O.D. |
| Suggested pad size |
10' x 12' x 6" thick |
10' x 12' x 6" thick |
| Gas service |
1,200,000 BTUH |
1,600,000 BTUH |
| Electrical service |
115V 60 Hz. 30 amp |
115V 60 Hz. 30 amp |
| |
P25
|
P25-M1
|
| LP |
Natural Gas |
LP |
Natural Gas |
| Fuel consumption* |
4.0 GPH |
400 CFH |
6.0 GPH |
600 CFH |
| Approximate BTUH: |
| Upper burner |
800,000 |
800,000 |
1,200,000 |
1,200,000 |
| Lower burner |
319,000 |
335,000 |
319,000 |
335,000 |
| *Fuel consumption
approximate. Actual fuel use depends on BTU content of
waste. Consult factory for longer retention times or